Beijer-electronics SCOM Protocol EN User Manual Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 131
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
Command Reference
Beijer Electronics, MAEN975 89
Example
Read the lower backlight level range limit configuration for the monitor at address
0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the lower backlight level range limit is 0 (0x00). This means, the user cannot adjust
the backlight level lower than the ECDIS backlight level, using the front panel key:
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x22 0xDC
0 1 2 3 4 5 6 7 8
0x06 0x07
0x4C 0x41 0x55 0x01 0x0F 0x00 0xFF
Page view 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 130 131

Comments to this Manuals

No comments