Beijer-electronics SCOM Protocol EN User Manual Page 83

  • Download
  • Add to my manuals
  • Print
  • Page
    / 131
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 82
Command Reference
Beijer Electronics, MAEN975 83
Example
Get the list of device addresses from the monitor at address 0.7 (group 0, address 7),
which are used to control other devices within its own group in a network, if the
broadcast mode is disabled:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitors at following addresses will be remote controlled, if remote controlling
is enabled and no broadcast address is used: 0.0, 0.3, 0.11 and 0.15 (group 0, address-
es 0, 3,11 and 15) (0x8809):
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x1E 0xE0
0 1 2 3 4 5 6 7...8 8
0x06 0x07
0x4C 0x41 0x55 0x02 0x0E 0x09 0x88 0xFF