Beijer-electronics SCOM Protocol EN User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 131
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
Command Reference
40 Beijer Electronics, MAEN975
Example 3
Decrement the current red channel level of monitor at address 0.7 (group 0, address
7):
Monitor at address 0.7 (group 0, address 7) has returned the new red channel level
189 (0xBD):
Example 4
Reset the red channel level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the default red channel level
128 (0x80):
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0xB4 0x2D 0x1E
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4D 0x43 0x43 0x04 0x1B 0xB4 0x2D 0x42 0x44 0x98
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4D 0x43 0x43 0x02 0x1C 0xB4 0x52 0xF9
0 1 2 3 4 5 6 7...10 11
0x06 0x07 0x4D 0x43 0x43 0x04 0x1B 0xB4 0x53 0x38 0x30 0x91
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 130 131

Comments to this Manuals

No comments