2.2 Grounding diagram
In order to reliably prevent electrical disruptions,
please note the following points:
Connect the PC and control cabinet as close to a central grounding
point as possible.
Make sure inductive connection between the computer and the
control cabinet is as low as possible.
All data cables connected to the computer have to be shielded
cables.
The shields have to be grounded on both ends. There must be a
low-impedance connection between the connected systems. Rule
out high equalizing currents through the shielding resulting from
potential differences.
The grounding connection with a green-yellow cable must be de-
signed with at least a 4 mm² cross-section.
2.3 Installation
Installation The industrial PC has to be installed in an HF- impermeable housing or
metal control cabinet.
In order to dissipate the heat emanating from the PC, 100 mm on three
sides of the PC must be kept clear so air can freely circulate.
The PC is assembled by screwing in eight hexagon nuts.
Caution!
Damage to the PC possible!
Front-end IP65 degree of protection is only guaranteed if the sealing sits
correctly on the front plate.
Once installed, 100 mm on three sides of the PC must be kept clear so
air can freely circulate
Caution!
The use of Compact Flash Card’s from different manufacturers can lead
to errors.
When using an internal and external Compact Flash card, only use cards
from the same manufacturer (same type and same size)
2.4 Switch on the PC
Start-up procedure The EPC boots up and loads the operating system.